PULSE VOLTAGE CONVERTER IPN
 |
|
Pulse
voltage converter is intended for power supply of any consumers
with the given in the table parameters of power supply voltage
and consumed current, namely of headlights of electric locomotive
ÀÌ8Ä (high, lower and orderly red), follows driving direction
of electric locomotive and automatically switches on the corresponding
headlight.
|
Basic parameters and sizes of a converter
Parameters |
Unit of measure |
Value of a parameter |
Note |
| 1. Nominal input voltage of power supply |
V |
50-200 |
direct current |
2. Output voltage U1
U2
|
V |
24(max1 A)
24(max4 A) |
direct current |
| 3. Consumed power |
Wt |
150 |
with max load current |
| 4. Regime of work |
|
long |
|
5. Overall dimensions, not more
length
width
height
|
mm |
220
140
60
|
|
| 6. Mass, not more |
kg |
7 |
|
Converter according to ÃÎÑÒ 27.003 belongs to the products of specific
purpose (ÈÊÍ), type II, which are subject to recovery, wear out,
repair.
Indexes of reliability and durability:
• error-free running time, h, not less 500;
• full lifetime, years, not less 5;
• average storageability time, years, not less 3.
The converter is resistant to outer affects of
mine environment for climatic performance of ÓÕË, category 5 according
to ÃÎÑÒ 15150 with the temperature of the environment from -100C
to +50 0C and relative air humidity to (98+2)% (with moisture condensation)
with the temperature +50 0C and dustiness not more than 1600 mg/m3.
Performance against implosion protection according to ÃÎÑÒ 12.2.050-76
for the group of application of PB1B.
Climatic performance of the converter Ó, category of placement 5
according to ÃÎÑÒ 15150.
|