CONSTANT-VOLTAGE UNIT IP-5
 |
|
IP-5 is intended
for electrical supply of lighting circuits and auxiliary equipment
of mine contact electrical locomotives and converts constant
voltage of 250 V into stabilized constant voltage of 24 V
with load current up to 15 A.
|
MAIN TECHNICAL DATA
| № |
Name
of parameters and sizes |
Unit measure |
Norm |
| 1 |
Nominal input voltage |
V |
250 +75/ -90 |
|
2 |
Nominal
output voltage
U1
U2
U3 |
V |
24±1
24±1
12±0,1 |
| 3 |
Load
current, nominal value
I1
I2
I3 |
А |
12
0,4
0,8 |
| 4 |
Load
current, minimum value |
А |
0 |
| 5 |
Threshold
of action of protection from current overloads
I1
I2. I3 |
А |
From
15,06 to 18,0
1,0 |
| 6 |
Consumption
current, not more |
А |
2,5 |
| 7 |
Overall
dimensions:
length
width
height
|
mm
|
310
182
116
|
| 8 |
Mass,
not more |
kg |
6 |
Output IP-5 is protected from short circuit from
the part of load. Coefficient of efficiency with nominal values
of input voltage and load current ИП not less than 80%. Pulsations
of output voltage on feeble-current outputs not more than 1%.
Electric insulation strength guarantees the absence of disruption
and surface covering of insulation during constant test voltage
of 2100 V in normal conditions of operation and 1500 V in conditions
of increased humidity during check-up between input and body, input
and output IP-5.
IP-5 must operate in the conditions of free air convection.
Working position is vertical (downwards with cable inputs), deviations
up to 5 grades from the working position to any side are assumed.
Protection level is 1P54 according to GOST14254-96. Temperature
of outside surfaces IP-5 during operation with nominal load does
not exceed 50 0C. Average error-free running time is not less than
1000 h with the temperature of 25 0C. Average lifetime taking into
account conduction of recovery work is not less than 10 years.
|